Download Agilent 3000 Micro Gc Manual
The Agilent 490 Micro GC is a rugged, compact, laboratory quality gas chromatograph that delivers information wherever you need it. Its modular design and MEMS technology-based components ensure flexibility, ease-of-use and unprecedented speed in gas analysis. Agilent 3000 Inficon Fusion Agilent 490 PRO Silicon Injector Chip MTI Chrompack Varian C2V SLS µGC Silicon micro GC Evolution Gas Only Analyzers. Retention times off due to manual injection. Green: BTEX 10 ppm Red: Headspace Bakken Oil microFAST GC Analysis. Page 50 and 51: Operation The 3000 Micro GC Portabl; Page 52 and 53: Operation The 3000 Micro GC Portabl. Page 54 and 55: Operation The 3000 Micro GC Portabl. Page 56 and 57: To shut down the Micro GC: Operatio. Page 58 and 59: Pressure regulator 1/4-inch NPT fit. Page 60 and 61: Checkout Run the checkout sample Tu. Page 62 and 63.
Parallel Interface (with or Without Serial Backpack) These screens have a parallel interface, which takes up a lot of pins on the Arduino. There are screens with a so-called serial backpack which makes it able to use UART to communicate with the display, resulting in a far lower amount of pins used. Aug 17, 2010 A serial LCD uses serial communications, a parallel LCD uses parallel communication. Ie: serial LCD uses a RX and TX line (allthough it likely doesn't use the TX), a parallel LCD uses 4 or 8 lines plus a 'clock' line (to make it accept the 4 or 8bits of data). Serial parallel interface. To the LCD and shows the time in seconds since the Arduino was reset. Output of the sketch on a 2x16 LCD The LCDs have a parallel interface, meaning that the microcontroller has to manipulate several interface pins at once to control the display.
INSTALLATION CHECKLIST INFICON 3000 Micro GC Installation Checklist IPN 074-543-P1B 1 of 3 To properly install the 3000 Micro GC, please consider the following items before the 3000 Micro GC installation service is delivered. Carrier Gas ..Recommend carrier gas (e.g., Helium, Argon) purity of 99.9995%, minimum 99.995% if appropriate carrier gas trap is installed.
Consult with INFICON for your specific instrument requirements. NOTE: A 2 channel 3000 Micro GC tank will last at least one year, application dependent. ..Dual Stage Regulator (CGA 580) for each carrier gas(s). Must be capable of delivering 80-82 PSI to the 3000 Micro GC. Regulator outlet fitting must be adapted to Swagelok ® in order to connect tubing.
Download Agilent 3000 Micro Gc Manual Free
Use 1/8' fittings or 1/8' adapters. ..Carrier Gas moisture/hydrocarbon filter (INFICON Part Number G2870A-01). These are recommended for use with Molecular Sieve and Alumina Modules. Tubing and Fittings ..Copper or stainless steel (pre-cleaned) 1/8' OD for carrier gas connections between tank regulator and 3000 Micro GC. 3000 Micro GC has a 1/8' Swagelok male carrier gas connection.
Download Agilent 3000 Micro Gc Manual
NOTE: Pre-cleaned 'GC' grade copper tubing in 50 ft. Lengths is included in INFICON 3000 Micro GC install kit G2860A or can be purchased from various chromatography vendors. NOTE: We do not recommend cleaning tubing with a solvent prior to use. NOTE: Do not use Teflon ® or Tygon ® tubing for the carrier gas. NOTE: Collection of male/female Swagelok fittings for regulator, tubing, etc. This includes nuts, front and back ferrules. Typical size is 1/8'.